What actually differs between panels
Industrial door panels are described by their face material and their core, and the two are frequently confused in specification. The face sets the mechanical behaviour — impact, weight, coating. The core sets the thermal behaviour. A panel is not "a steel door" or "an insulated door"; it is a combination, and the useful comparison is between combinations.
Three constructions cover most of the market, and the choice between them changes more than the panel price.
The three constructions
Steel-faced, insulated core. Two hot-dip galvanised steel skins bonded to a polyurethane core, 40 mm total. The core carries the insulation and adds stiffness, so the leaf does not need a separate bracing frame to stay flat in wind. This is the default industrial construction.
Aluminium-faced. Aluminium skins, usually on a framed panel rather than a bonded sandwich, because aluminium is less stiff per unit thickness and needs a deeper section to carry the same load. The reason to choose it is weight, not performance.
Thin single-skin steel. A single steel sheet, sometimes with a shallow profile. It looks like a panel and behaves differently: no meaningful thermal performance, and a leaf that flexes in wind. It exists because it is cheap, and it should be recognised for what it is.
| Aspect | Steel-faced insulated | Aluminium-faced | Single-skin steel |
|---|---|---|---|
| Face density | Steel | About a third of steel | Steel, but only one skin |
| Thermal performance | Panel 0.84 W/(m²·K), joint 0.4 | Depends on the core; framed panels vary | Negligible |
| Stiffness in wind | Core provides it | Needs a deeper frame section | Flexes; limited width |
| Impact behaviour | Deforms and recovers | Dents permanently | Deforms easily |
| Leaf weight | Heaviest | Lightest of the three | Light |
| Where it belongs | General plant and warehouse openings | Large spans, limited header capacity, glazed leaves | Cost-driven openings with no thermal requirement |
What the face changes downstream
The face material does not stay a panel decision. It propagates through the whole door.
Into the counterbalance. Springs are sized to the leaf weight. A heavier face means a heavier leaf, which means more spring energy, a larger shaft and a heavier cable specification.
Into the structure. The door transfers wind load into the building through its fixings, and a heavier leaf adds to the load. On a light steel frame or a thin wall, this can be the constraint that decides the product.
Into the drive. Not because the motor lifts the leaf — the springs do that — but because a heavier leaf needs more force to accelerate and more brake to stop.
Into the manual operation. The 150 N manual opening force is achievable on any of these leaves if the counterbalance is correct, but it is easier to achieve on a lighter one.
What the core changes
The core is where insulation lives, and two numbers describe it: density and thermal conductivity. On this product family the measured core density is 44 kg/m³ and the conductivity is 0.023 W/(m·K), producing the 0.84 W/(m²·K) panel figure.
Density matters twice. It sets the mass of the panel, and it sets the stiffness — a low-density core does not hold the skins apart under load, so the panel deflects and the insulation degrades where it flexes. A panel that quotes a good conductivity but has a low-density core is a panel that performs on the day it is tested.
The reaction to fire of the assembly is DIN 4102-1 B2. That is a material classification, not a fire resistance rating of the door, and the distinction matters in any submission where a fire strategy is involved.
How to tell what you are being offered
Ask for three things and the answer identifies the construction.
The panel U-value with a test report reference. A construction that has one quotes it; a single-skin panel cannot.
The core density. A supplier who knows it is describing a panel; one who does not is selling a thickness.
The leaf weight for the opening. This is the number the counterbalance is based on, and a supplier who cannot state it cannot have sized the springs.
None of these is difficult to answer honestly. A quotation that omits all three is not a specification.
Matching the panel to the duty
For a general plant or warehouse opening, the steel-faced insulated panel of the steel lifting door is the default and the best value — it holds a boundary and survives contact. Where the header cannot carry a heavy leaf, or the leaf is mostly glazing, aluminium becomes the right answer despite the impact trade; that case is set out under the aluminium lifting door page.
Where the duty is thermal with a large differential, the panel is the same construction but the track and rail detail change, which is the subject of the insulated lifting door page. And where a single-skin panel is being offered at a price that looks too good, the absence of a U-value is usually the explanation.
Frequently asked questions
Is an aluminium panel less insulated than a steel one?
Not because of the face — insulation comes from the core. What differs is that aluminium panels are usually framed rather than bonded, and the frame is a thermal path the core does not cover.
Does a thicker panel always insulate better?
Thickness and conductivity together produce the U-value. A thick panel with a poor core can perform worse than a thinner one with a good core, which is why density matters.
Why does the joint have a lower U-value than the panel?
Because two compressed panel edges present a longer heat path than one panel through its thickness. It is geometry, not a better material.
Can a single-skin panel be upgraded later?
The panel can be replaced, but the door was sized around the original weight. A heavier replacement panel changes the counterbalance requirement, so it is not a like-for-like swap.
What does the panel weight do to the building?
It adds to the load at the header and to the load the fixings carry. On a light structure that can be the constraint that rules out a steel-faced leaf.