Industrial Sectional Door
Sectional overhead door for openings up to 6.0 m high and 12.0 m wide: 40 mm insulated panel, 450 N/m² wind load, 2.2 kW drive, EN 12453 safety edge.
- Panel thickness
- 40 mm (double-skin hot-dip galvanised steel + polyurethane core)
- Core density
- 44 kg/m³ (measured, test report JSJCJ-QT-200810-08)
- Thermal conductivity
- 0.023 W/(m·K)
- Wind load resistance
- 450 N/m² (Beaufort 10, wind ribs optional)
What an industrial overhead door is
An industrial overhead door is a sectional door whose panels rise vertically along side tracks and park horizontally beneath the ceiling. Because the leaf travels upward rather than swinging out or rolling sideways, the opening keeps its full clear width, and neither the wall beside the opening nor the floor in front of it is occupied by the door. That single property explains why this type dominates factory and warehouse openings that forklifts and trucks have to pass through many times a day.
The door covered on this page is built for openings up to 6.0 m high and 12.0 m wide, with a 40 mm polyurethane-cored panel and a 2.2 kW drive. It sits in the wider family of industrial sectional doors, alongside the insulated overhead door used for cold storage transitions and the high-lift and vertical-lift variants used where ceiling height or overhead services restrict a standard track layout.
Panel, track and frame construction
The leaf is a stack of hinged panels. Each panel is a steel face sheet bonded to a polyurethane core, 40 mm total thickness, which is what separates this door from a single-skin shutter: the core carries the insulation value and adds stiffness, so the panel resists deflection across a 12 m width without a separate bracing frame.
Panels are joined by hinges that allow the leaf to articulate as it passes from the vertical track into the horizontal one. The transition is the mechanically loaded part of any overhead door, which is why the track radius, the hinge spacing and the roller diameter have to be matched to the panel weight rather than selected independently. On this build the complete leaf weighs about 2000 kg, and the counterbalance is set to that figure — changing panel type or glazing afterwards without re-balancing the springs is the most common cause of a door that drifts or drops.
The frame carries the vertical tracks, the horizontal tracks and the shaft. It must be anchored into structure, not into cladding: wind load on a 12 m wide leaf is transferred to the building through these anchor points, and a cladding fixing will pull out long before the door reaches its rated pressure.
Technical data
These are the values for the build described on this page. They are not a range across the product family — a different opening size or a different panel type will change the drive rating and the counterbalance setting.
| Parameter | Value |
|---|---|
| Panel thickness | 40 mm (double-skin hot-dip galvanised steel + polyurethane core) |
| Core density | 44 kg/m³ (measured) |
| Thermal conductivity | 0.023 W/(m·K) |
| Reaction to fire | DIN 4102-1 B2 |
| Wind load resistance | 450 N/m² (Beaufort 10) |
| Maximum opening height | 6.0 m |
| Maximum opening width | 12.0 m |
| Lifting speed | 0.25-0.3 m/s |
| Leaf weight | 2000 kg |
| Motor power | 2.2 kW |
| Operating noise | ≤60 dB |
| Manual opening force | ≤150 N |
The core values are not catalogue claims: they come from a test report on this panel, issued by the Jiangsu polyurethane product quality inspection station under report number JSJCJ-QT-200810-08. The density and thermal conductivity figures above are the measured values from that report, and the fire classification is its DIN 4102-1 B2 finding. If a project needs the paperwork, that is the document to ask for — not a datasheet.
Wind load is the figure most often misread. 450 N/m² is a pressure, not a wind speed, and it corresponds to Beaufort 10. It is also only valid for the anchoring and bracing supplied with the door: a door rated at 450 N/m² and installed into a lightweight wall does not deliver 450 N/m² in service. Where the opening faces open ground or a coastal site, the pressure class has to be agreed together with the structural fixing detail, following the classification in EN 12424.
How the lifting mechanism works
The drive turns a shaft that carries cable drums at each end. Cables run from the drums to the bottom panel, and torsion springs on the shaft carry the weight of the leaf. The motor therefore lifts only the difference between the leaf weight and the spring torque, which is why a 2000 kg leaf can be moved by a 2.2 kW motor without overheating.
Operation is a chain of states rather than a single action: the controller releases the brake, the motor runs until the limit switch for the requested position is reached, and the brake re-engages. The limit switches are mechanical settings and they move over time — a door that stops 20 mm short of the floor after a year is usually a limit switch that has drifted, not a failed motor.
Manual release is provided for power failure. On a leaf of this weight the release is a deliberate, two-hand operation, and the door should be brought down under control rather than allowed to run. Anyone specifying this door for a site with frequent power interruption should say so at order stage, because the release arrangement differs from the standard build.
Sealing, insulation and wind load
Three separate seals do three separate jobs. The bottom seal compresses against the floor and closes the gap that would otherwise let water and draught through. The side seals run in the vertical track and close the gap between panel edge and frame. The top seal closes against the header. A door with a good bottom seal and worn side seals still leaks, and the leak is invisible from inside the building.
The 40 mm polyurethane core gives the panel its thermal resistance, but thermal performance of the opening is decided by the edges, not the field of the panel. That is why cold-store installations use a heated rail and a bottom seal that stays flexible at low temperature: without rail heating, condensation on the track freezes and the door either stalls or tears its own seals. The same detail is what the frost-prevention feature on this build refers to.
Safety and control
The door is driven by a motor, so it falls under the machinery safety requirements for power-operated doors, EN 12453, with the test methods in EN 12445. In practice this means the installation has to detect an obstruction before the leaf closes on it, and has to limit the closing force. A safety edge on the bottom panel plus a pair of photocells across the opening is the usual arrangement for a door of this size; a single photocell alone is not sufficient where pedestrians share the opening with vehicles.
Control options on this build include remote monitoring, so door state and fault codes can be read without walking to the door. That is useful on a site with several doors, where the first sign of a problem is otherwise a phone call from the loading supervisor. It does not replace the physical safety devices — monitoring tells you the door is faulted, it does not stop the door.
Where this door fits
The size range points at a specific set of openings. It suits factory bays and warehouse ends where a forklift plus load has to pass without slowing, and where the opening is too wide for a roller shutter to stay rigid in wind. It suits production halls where the door is part of the thermal envelope, because the insulated panel and the three seals are what hold the temperature at the opening. It also suits loading areas where the door has to stay open for long stretches during a shift and closed and sealed overnight.
It is a less obvious choice where the opening is small and traffic is light: below roughly 3 m wide there is little to gain from a sectional door over a high-speed roll-up, and the sectional door costs more per square metre of opening. For cold chain transitions where the door opens dozens of times an hour, the decision usually comes down to cycle speed rather than insulation, which is why cold chain door solutions often pair an insulated overhead door at the outer wall with a fast door at the inner partition. Food plants add hygiene requirements on top of that, covered under food industry door solutions.
Choosing the right configuration
Most specification errors on this door type come from four decisions taken in the wrong order. The table below lists what to settle first, and what it changes.
| Site condition | What it changes |
|---|---|
| Opening taller than the standard lift allows | Track layout becomes high-lift or vertical-lift, which changes the shaft position and the spring calculation |
| Opening exposed to cross wind | Wind pressure class and the anchor detail into structure both have to be raised together |
| Door on a cold store boundary | Rail heating and a low-temperature bottom seal, otherwise condensation freezes on the track |
| Pedestrians sharing the opening | Safety edge plus photocells, and a separate pedestrian door rather than a pass door cut into the leaf |
| Frequent power interruption | Manual release arrangement agreed at order stage, not assumed to be standard |
Two of these change the mechanical build and cannot be retrofitted cheaply: the track layout and the wind class. The other three are additions to a standard door and can be decided later, at higher cost. Getting the first two right at quotation stage is the difference between a door that lasts its service life and one that is re-specified after two winters.
Pricing and quotation
Every door is made to order. Because each unit is built to the actual clear opening, there is no fixed price list and no standard price range - the price changes with the opening width and height. It also depends on the panel or curtain specification, drive and control package, safety devices, fixing structure, site conditions and delivery location. Send the opening dimensions (width x height), the expected number of opening cycles per day and the installation address, and we will quote the exact configuration. Use the quote button above or the contact page to request a quotation.
Installed door photographs
Photographs of this door family installed in industrial and logistics buildings. Door dimensions, panel colours, vision panels and track arrangements differ from project to project because every unit is made to measure.



This section documents the engineering, service and compliance baseline for the Industrial Sectional Door.
Working principle and construction
A sectional door leaf is a chain of hinged, insulated panels carried in side tracks. As the operator winds the cable drums, the panels travel vertically, turn through the track radius and park horizontally under the ceiling; torsion springs counterbalance the leaf so the motor only overcomes friction and inertia. The lift arrangement - standard lift, high lift or vertical lift - is chosen from the measured headroom, side room and ceiling obstructions. Project-specific shop drawings are issued only after the on-site survey.
| Component | Function | Industry-typical configuration |
|---|---|---|
| Insulated panels | Leaf and thermal barrier | 40-50 mm double-skin galvanised steel with PU core (typical) |
| Side tracks and radius | Define the lift path | Standard / high / vertical lift, selected from measured headroom |
| Torsion springs | Counterbalance the leaf | Sized to leaf weight, rated over 50,000 cycles (indicative) |
| Drive and control | Lift and hold | 3-phase motor or shaft drive with limit switches / encoder |
| Safety set | Protect people and vehicles | Bottom safety edge, spring-break device, photocells (EN 12453) |
Technical drawings (general arrangement, section details and opening schedule) are issued per project after the on-site survey. No downloadable CAD file is claimed for this door family on this page; use the quotation button to request the current drawing set.
Service, warranty and project support
The levels below are industry-typical service terms used as a working basis because Anbixin's own policy schedule has not yet been supplied. They are indicative and are confirmed or adjusted in the written quotation and service agreement for each project.
- Warranty: 24 months on the door leaf, drive unit and control package from handover; wear items (seals, brushes, curtain fabric, impact damage) are excluded. Extended warranty terms can be quoted.
- After-sales support: acknowledgement within one working day, remote diagnostics for control faults, on-site attendance subject to location and schedule; common wear parts are kept available for replacement.
- On-site survey: measurement of clear width and height, headroom, side room, fixing structure, power supply and traffic pattern, followed by project-specific shop drawings before fabrication.
- Preventive maintenance: scheduled service visits with counterbalance check, safety-device function test, seal inspection and lubrication; panel, slat or curtain replacement is available.
- Project and volume pricing: tiered pricing for project orders, contractors, partners and multi-unit purchases; applicable terms are stated in the quotation, not as a published discount rate.
Nothing on this page constitutes a binding service commitment. Confirm warranty duration, response times, survey coverage and project pricing with the sales team before including them in a tender, advertisement or contract.
Standards, safety and compliance
Design and safety references for this product family: EN 13241 (product standard for industrial, commercial and garage doors), EN 12453 and EN 12445 (safety in use of power-operated doors and the related test methods), EN 12604 (mechanical requirements), EN 12424 and EN 12444 (wind-load classification and test), EN ISO 13849-1 (safety-related parts of control systems) and EN 60204-1 (electrical equipment of machines). These are design and test references, not a claim of certification: compliance, test reports and any third-party certificate are confirmed per project in the technical submittal. Fire-rated roller shutters belong to a separate product family selected to the fire-compartment requirements, where EN 13501-1 and EN 1634-1 apply; this page does not claim a fire rating.
Vietnamese market terminology
In Vietnam this door family is searched with the local Vietnamese terms listed below. Buyers search in Vietnamese, so these terms are kept untranslated here and used in headings, FAQs and metadata. Literal English-style translations such as 'electric lifting door' or 'vertical lifting door' are rarely used locally.
- cửa cuốn công nghiệp — industrial overhead sectional door
- cửa nâng phân đoạn — sectional lift door
- cửa trượt trần panel — panel overhead sliding door
- cửa cuốn nâng — lifting roll-up door
Typical applications in the Vietnamese market

Sectional lift door · clean-area partition
Partition between clean and general areas; smooth, easy-clean panel surface, usually combined with a pedestrian door in the same opening.

Sectional lift door · workshop to store
Transfer opening between workshop and finished-goods store; high-lift or vertical-lift track where ceiling height allows.

Sectional lift door · loading bays
External vehicle opening of a factory building, insulated panels separating temperature zones; typical clear width 3-8 m.
Photographs below are from installations of this door family in Vietnam. Customer names are withheld; project details are available on request.
Frequently asked questions
How much clear space does the door need above the opening?A standard lift needs horizontal track roughly equal to the door height plus the spring and shaft assembly above the header. Where that space is not available, the door is built as a high-lift or vertical-lift layout instead. The space requirement is a property of the track layout, not of the panel, so it has to be fixed before the opening is built.
Yes, and this is one of its main uses. The 40 mm polyurethane core and the three seals provide the thermal separation. For a cold store boundary, rail heating and a low-temperature bottom seal are added, because the limiting factor at low temperature is ice on the track rather than conductivity through the panel.
The drive has a manual release. On a 2000 kg leaf this is a controlled two-hand operation, and the door is brought down or up under control rather than released to run. Sites with frequent outages should specify the release arrangement at order stage.
The standard requires the installation to detect an obstruction and to limit closing force. A safety edge addresses the closing edge; where pedestrians share the opening with vehicles, photocells are added to detect a person before the leaf reaches them. The combination is what the standard is applied to, not a single device.
The spring setting is matched to the leaf weight, so it is checked whenever anything changes the leaf: a panel replaced, glazing added, a different bottom seal fitted. Routine inspection intervals depend on cycle count and should be set with the maintenance schedule for the door rather than on a fixed calendar.
Pain Points Solved
Traditional industrial doors often have poor sealing, leading to heat loss or the entry of external dust, which can affect equipment operation efficiency and workshop environment.
Key Features
- Up to 6.0 m high and 12.0 m wide, for large factory openings
- 40 mm insulated panel with 44 kg/m³ core
- External torsion springs rated over 50,000 cycles
- Manual opening force does not exceed 150 N
Technical Specifications
| Panel thickness | 40 mm (double-skin hot-dip galvanised steel + polyurethane core) |
|---|---|
| Core density | 44 kg/m³ (measured, test report JSJCJ-QT-200810-08) |
| Thermal conductivity | 0.023 W/(m·K) |
| Wind load resistance | 450 N/m² (Beaufort 10, wind ribs optional) |
| Lifting speed | 0.25-0.3 m/s |
| Balance system | External torsion springs, rated over 50,000 cycles |
| Operating noise | ≤60 dB |
| Manual opening force | ≤150 N |
| Maximum opening height | 6.0 m |
| Maximum opening width | 12.0 m |
| Leaf weight | 2000 kg |
| Motor power | 2.2 kW |
| Safety devices | Pneumatic bottom safety edge; spring break device stops the leaf within 20 cm |
| Seals | PVC seals on top, bottom and both sides, low-temperature resistant |
Gallery
Need a Reliable Solution for Your Project?
Tell us about your application and requirements — our team will help you specify the right product.